Home > Technical Articles

What is EN ISO 11666:2010+A1:2013

EN ISO 11666:2010+A1:2013 is a technical standard that provides guidelines for the determination of carbon and sulfur in iron and steel samples. This standard is widely used in the manufacturing and quality control of iron and steel industries. In this article, we will discuss the importance of this standard, its key components, and the methods it recommends for analysis.

Importance of EN ISO 11666:2010+A1:2013

The accurate measurement of carbon and sulfur content in iron and steel is crucial for ensuring the integrity and quality of the final product. Excessive amounts of these elements can negatively impact the mechanical properties, corrosion resistance, and overall performance of the material. EN ISO 11666:2010+A1:2013 plays a critical role in establishing reliable analytical procedures to determine these elements.

This standard provides clear guidelines on sample preparation, instrument calibration, and measurement techniques. It ensures that all laboratories following these guidelines produce consistent and comparable results. This enables better control over the production process, leading to improved product quality and customer satisfaction.

Key Components of EN ISO 11666:2010+A1:2013

EN ISO 11666:2010+A1:2013 covers various aspects related to carbon and sulfur determination. It includes procedures for both combustion-infrared absorption and coulometric titration methods. These methods offer different levels of precision and accuracy depending on the specific requirements of the analysis.

The standard also specifies the necessary equipment and apparatus needed for the analysis, such as combustion furnaces, infrared absorption analyzers, and coulometric titrators. It outlines the calibration procedures for these instruments to ensure accurate measurements.

Analysis Methods Recommended by EN ISO 11666:2010+A1:2013

EN ISO 11666:2010+A1:2013 recommends the use of combustion-infrared absorption and coulometric titration methods for carbon and sulfur determination. The combustion-infrared absorption method involves burning the sample in a high-temperature furnace to release the carbon and sulfur gases, which are then measured using an infrared absorption analyzer.

On the other hand, the coulometric titration method employs an electrochemical technique to determine the carbon and sulfur content. It involves the electrolysis of a solution containing the sample, leading to the deposition of these elements onto specific electrodes. The amount of electricity consumed during the process is used to calculate the carbon and sulfur concentrations.

Both methods have their advantages and limitations, and the choice depends on factors such as sample matrix, required detection limits, and available resources. Following the recommended procedures ensures accurate and reliable results that can be compared across different laboratories.

CONTACT US

Contact: Nina She

Phone: +86-13751010017

Tel: +86-755-33168386

Email: sales@china-gauges.com

Add: 1F Junfeng Building, Gongle, Xixiang, Baoan District, Shenzhen, Guangdong, China

close
Scan the qr codeClose
the qr code